The store will not work correctly when cookies are disabled.
Leybold RA 9001 - REBUILT
Weight |
3307 lbs |
Motor Power |
29.5 hp |
Pumping Speed |
9720 m3/h |
Ultimate Pressure |
6.6 x 101 mbar |
Leybold RUVAC RA 9001 Roots Vacuum Blower - REBUILT
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
RUVAC RA |
3001 |
5001 |
7001 |
9001 |
13000 |
Nominal pumping speed |
m3 x h-1 |
3,900 |
5,550 |
7,470 |
9,720 |
13,000 |
Maximum pumping speed - at pumping speed for the backing pump |
m3 x h-1 m3 x h-1 |
3,300 630 |
5,000 1,260 |
6,800 1,850 |
8,800 1,850 |
12,000 2,600 |
Maximum allowable pressure differential - in continuous operation - for less than 3 minutes |
mbar mbar |
53 93 |
66 133 |
53 93 |
Mains voltage at the motor, 50 Hz |
|
380 - 420 V / 660 - 725 Y |
Mains voltage at the motor, 60 Hz |
|
440 - 480 V Æ |
Motor power, 50 Hz |
|
11 kW |
15 kW |
18.5 kW |
22 kW |
30 kW |
Protection |
|
IP 54 |
Trigger temperature for the PTC resistors |
|
130°C |
Nominal speed at 50 Hz |
min-1 |
3,000 |
1,500 |
2,000 |
Max. permissible speed |
min-1 |
3,600 |
3,000 |
1,800 |
2,000 |
Oil filling, approx. - vertical flow - horizontal flow |
liters |
7 3.5 |
12 5.4 |
11 7.6 |
Noise level |
dB (A) |
77 |
78 |
79 |
69 |
72 |
Weight, complete, approx. |
kg |
620 |
770 |
870 |
1,500 |
- |
Intake / discharge flange |
DN |
200 |
250 |
300 |
Permissible ambient temperatures |
°C |
12 - 40 |
RUVAC RA w/ motor coupling & lantern |
Part # |
119 50 |
119 53 |
119 60 |
119 63 |
Custom |
Specifications
Type |
Label |
Description |
Download |
|
Leybold RUVAC RA Series - REBUILT |
Instruction Manual |
Download
|
Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs.
Leybold RUVAC RA 9001 Roots Vacuum Blower - REBUILT
11963 / 119 63