Advanced Energy MDX-10K Slave
Call for Price
USED Advanced Energy AE MDX-10K DC Magnetron Slave Unit 3152012-043
The Advanced Energy AE MDX-10K DC Magnetron 3152012-043, has a passive front panel that replaces the standard front panel, it is configured for use as a slave and the software has been changed. The unit features an interlock rear panel, and the out-of-setpoint timer has been preset to 20.4 seconds.
Output Impedance Range
Each MDX is equipped with a built in impedance matching transformer. These tap-selectable transformers are available in high Z, standard Z or low Z configurations. With the proper transformer and tap, load impedances requiring voltages from 400 V to 1,250 V can be accommodated.
Output Regulation
The MDX can be used as a power, current or voltage source, depending on the method of output regulation selected. Since setpoint levels are stored in nonvolatile memory, they can be used in recovering from input power interruptions and to ensure repeatability from run to run.
The MDXL is DC magnetron source by rectifying a switching frequency of 17 - 31 kHz. The Sparc-le integrates into existing systems with both old and new MDX products.
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
Specifications | MDX 5K | MDX 10K | MDX 15K | MDX 20K | MDX 25K | MDX 30K |
---|---|---|---|---|---|---|
Input voltages | 200 or 208 VAC rms ± 10%, 50/60 Hz, three-phase "Y" connection; maximum ground leakage current less than 3.5 mA | |||||
Input current | 200 or 208 VAC full load | |||||
Maximum current (at -10% input line voltage) | 19 A | 38 A | 57 A | 76 A | 95 A | 114 A |
Output power | 0-5000 W | 0-10,000 W | 0-15,000 W | 0-20,000 W | 0-25,000 W | 0-30,000 W |
Chassis per system | 1 | 2 | 3 | |||
Output ripple voltage (% rms) | 5 | 2 | ||||
Output ripple frequency | 50 kHz | 100 kHz | ||||
Output display accuracy | Within 2% of actual output level or 0.2% of maximum rated output level, whichever is greater | |||||
Target accumulator | Target life is displayed in 1-kWl increments; the counter is updated every 4.7 ms | |||||
Methods of control | Full or restricted access, local or remote control, programmed or manual operation | |||||
Output connector | UHF type, Amphenol part number 83-822 (mate supplied) or terminal block | |||||
Output cable | RG-8U coaxial cable and/or discrete cables | |||||
Size | 7" (H) x 19" (W) X 19" (D) (17.8 cm x 48.3 cm x 48.3 cm) | |||||
Weight | 55 lbs (25 kg) | 71 lbs (32.3 kg) | ||||
Ambient temperature | ||||||
Operating | Minimum 0°C, maximum 40°C (maximum value of average over 24 hr.:35°C). If the units are enclosed in cabinets, the operator will ascertain the temperature at the place of instalation and ensure that the macimum ambient temperature is not exceeded. | |||||
Storage | Minimum -25°C, maximum 55°C | |||||
Transportation | Minimum -25°C, maximum 55°C (for short periods of up to 24 hr., the maximum is 70°C) | |||||
Coolant temperature | Air (gas) minimum 0°C, maximum 35°C | |||||
Coolant flow parameters | ||||||
Contamination | Cooling air should be free of corrosive vapors and particles, conductive particles, and particles that could become conductive after exposure to moisture. | |||||
Humidity | 15-85% relative humidity; no condensation or icing | |||||
Atmospheric pressure | ||||||
Operating | 800 mbar minimum (approx. 2,000 m above sea level) | |||||
Storage | ||||||
Transportation | 660 mbar minimum (approx. 3,265 m above sea level) | |||||
Maximum output current: low impedance ("Low Z") | ||||||
Tap 1 / 0 to 500 V output range | 12.50 A | 25.00 A | 37.50 A | 50.00 A | 62.50 A | 75.00 A |
Tap 2 / 0 to 640 V output range | 10.00 A | 20.00 A | 30.00 A | 40.00 A | 50.00 A | 60.00 A |
Tap 3 / 0 to 800 V output range | 7.75 A | 15.50 A | 23.50 A | 31.00 A | 38.75 A | 46.50 A |
Maximum output current: standard impedance ("Standard Z") | ||||||
Tap 1 / 0 to 600 V output range | 10.00 A | 20.00 A | 30.00 A | 40.00 A | 50.00 A | 60.00 A |
Tap 2 / 0 to 800 V output range | 8.00 A | 16.00 A | 24.00 A | 32.00 A | 40.00 A | 48.00 A |
Tap 3 / 0 to 1,000 V output range | 6.25 A | 12.50 A | 18.75 A | 25.00 A | 31.25 A | 37.50 A |
Maximum output current: high impedance ("High Z") | ||||||
Tap 1 / 0 to 775 V output range | 8.00 A | 16.00 A | 24.00 A | 32.00 A | 40.00 A | 48.00 A |
Tap 2 / 0 to 1,000 V output range | 6.40 A | 12.80 A | 19.20 A | 25.60 A | 32.00 A | 38.40 A |
Tap 3 / 0 to 1,250 V output range | 5.00 A | 10.00 A | 15.00 A | 20.00 A | 25.00 A | 30.00 A |
Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs.