Advanced Energy PDX 900-2V

Call for Price

In stock
SKU
USED_PDX-900-2V

USED Advanced Energy AE PDX 900-2V RF Plasma Generator

The PDX series of low-power (1,250 and 1,400 W) and high-power (5,000 and 8,000 W) mid-frequency power supplies offers a highly efficient, compact, easy-to-integrate source of power for a wide variety of process applications. These highly reliable power supplies enhance process flexibility, deliver a wide operating frequency range for optimized process control, ensure high process repeatability, and improve throughput.

Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!

Control signal sources Output is controlled by remote signals provided to the Generator User connector. (The tap select function is controlled from the front panel.)
Methods of output regulation The PDX regulates output based on load power. In load power regulation, the forward power measured at the output connector can vary to keep the power dissipated in the load constant.
Load matching The output has a load-matching transformer. The transformer's seven taps allow the PDX to efficiently transfer power. The PDX 900-2V has a load-matching range of 25 to 125 n (unbalanced).
Fault conditions Three conditions cause the PDX to shut off output power: overtemperature, line fault, and arc (if arc latch is active). Fault conditions are indicated by two LEDs on the front panel and one LED on the rear panel.
Limit conditions Limit conditions require attention, but do not shut off output power. A limit condition has occurred if the setpoint LED is not lit for output power above 50 W. The five possible conditions are voltage limit, current limit, reflected power limit, forward power limit, and arc (if arc latch is not active)
Size 3.5" (H) x 19" (W) x 20" (D) (8.9 cm x 48.3 cm x 50.8 cm)
Weight 30 lb. (13.6 kg)
User connector 25-pin, male, subminiature-D
RF output connector Type N
Load-matching output connector     Type C
Input connector Hubbell 2621 (North America only)
RF output power 8 W minimum, 900 W maximum, accuracy is 1 % of setpoint or 2 W, whichever is greater
Reflected power 250 W maximum (measured before loadmatch transformer)
Regulation Load power regulation modes
Harmonics At 900 W at 350 kHz (into a 50 n load), all harmonics are nominally greater than 45 dB below the fundamental output frequency
Frequency 350 kHz
Output voltage for 50-Ω output 300 V maximum
Output voltage for output A 850 V maximum
Output current 6.0 A maximum
Load impedance 25 to 125 n (7 steps) loadmatch transformer
Input voltage 200 to 230 VAC, 50/60 Hz, single phase
Input current 10 A rms maximum at 200 VAC input
Line input connection 6 ft., 3-wire, 14 AWG with Hubbell connectors. (North America only. No line cord or connector is provided with European units)
Internal power dissipation 250 W maximum
Noise < 70 dB
Ambient temperature  
    Operating Class 3K3. Minimum 0°C, maximum 40°C (maximum value of average over 24 hr.: 35°C). If the units are enclosed in cabinets, ensure that the maximum ambient temperature is not exceeded
    Storage Class 1 K4. Minimum -25°C, maximum 55°C
    Transportation Class 2K3. Minimum -25°C, maximum 55°C (for short periods of up to 24 hr., the maximum is 70°C)
Humidity Class 3K3. 5 to 85% relative humidity; no condensation or icing
Atmospheric pressure  
    Operating 800 mbar minimum (approx. 2,000 m above sea level)
    Storage 800 mbar minimum (approx. 2,000 m above sea level)
    Transportation 660 mbar minimum (approx. 3,265 m above sea level)
Pollution degree Two. Only non-conductive pollution occurs