Advanced Energy Sparc-le 20

Call for Price

In stock
SKU
USED_Sparc-le-20

USED Advanced Energy AE Sparc-le 20 DC Pulsing ARC Handling Interface 3152244-024

The Sparc-le 20 3152244-024 clears arcs in 5ms and reduces the number of hard arcs, resulting in reduced particulates and increased process time. Its small size allows for easy integration into existing systems with both old and new MDX products.

Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!

DC input & output connectors UHF type, female, Amphenol part number 83-1R Optional: 2-position terminal block or MS-3470 connectors (male for input, female for output)
Cable connector for DC input & output     UHF type, male, Amphenol part number 83-822 Optional: terminal block or MS-3476 connector
DC input & output cables RG-8U coaxial cable; output cable from Sparc-le 20 to chamber not to exceed 6 m (20 ft.)
Size 13.3 cm x 48.3 cm x 19.4 cm (5.25" (H) x 19"(W) x 7.65" (D))
Weight 7.7 kg (17 lbs) maximum
AC input voltage 90 to 126.5 VAC rms, 50/60 Hz, single phase, 30 VA 180 to 253 VAC rms, 50/60 Hz, single phase, 30 VA
DC input voltage Any low-Z or standard-Z output from an MDX magnetron supply
DC current 25 A steady state maximum. No minimum current is required for operation. The supervisory circuit requires a minimum of 1.5 A before it is operational. Note: Low power Sparc-le 20 units should be operated only up to 3 A.
Input & output DC polarity Negative output (positive at ground); Negative output (positive floating less than 100 V from ground)
Reverse recovery voltage 10% of input voltage
Arc-handling characteristics 40,000 arcs/sec. maximum; 4 to 6 μs typical arc recovery time; 1,800 V absolute maximum input dc voltage; 150 V minimum to 1,000 V maximum output operating range; 7 to 11 μs delay before next arc can be processed
Ambient temperature
    Operating Minimum 0ºC, maximum 40ºC (maximum value of average over 24 hr.: 35ºC)
    Storage Minimum -25ºC, maximum 55ºC
    Transportation Minimum -25ºC, maximum 55ºC (for short periods of up to 24 hr., the maximum is 70ºC)
Coolant flow parameters
    Contamination Cooling air should be free of corrosive vapors and particles, conductive particles, and particles that could become conductive after exposure to moisture.
    Humidity 15% to 85% relative humidity; no condensation or icing
Atmospheric pressure
    Operating 800 mbar minimum (approximately 2,000 m above sea level)
    Storage 800 mbar minimum (approximately 2,000 m above sea level)
    Transportation 660 mbar minimum (approximately 3,265 m above sea level)

Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs.

USED Advanced Energy AE Sparc-le 20 DC Pulsing ARC Handling Interface 

3152244024 / 3152244-024